calculating the size of a thickener

thickeners amp; clarifiers   MIP Process Corp

thickeners clarifiers MIP Process Corp

available. Thickener tanks, rakes and feedwells are custom designed, based on the feed conditions and raking capacity. A retrofit service is offered to enhance performance of existing thickeners and clarifiers. tHiCkener design MIP Thickeners and Clarifiers are designed to

Live Chat
Improve Clarifier and Thickener Design and Operation

Improve Clarifier and Thickener Design and Operation

The thickener area is also required for this calculation. Guess the thickener area for the first iteration. Several iterations of area may be required to achieve a practical thickener size and pumping rate. For a circular thickener with a 15.24 m (50 f t) dia. A= Pi r 2 = 182.4 m 2 (7)

Live Chat
How to Size a Thickener   Mineral Processing amp; Metallurgy

How to Size a Thickener Mineral Processing Metallurgy

Knowing how to size a thickener and determine the capacity required to handle a pre determined tonnage of a certain pulp, by overflowing a clear solution and obtaining the desired pulp density of thickener discharge, depends upon the settling rate of that particular pulp. The settling rate of any pulp is easily determined by simple laboratory tests such as outlined below Laboratory Test

Live Chat
Thickeners   solidliquid separation

Thickeners solidliquid separation

To take a thickener out of commission for repairs inside the tank such as damaged blades, or rubber lining may take days since it requires to empty the tank, remove the underflow bed, refill it and find a suitable storage or disposal site for very large volumes of liquid.

Live Chat
Calculating Grease Quantity, Frequency

Calculating Grease Quantity, Frequency

Use this handy tool as a general guideline for establishing grease frequency and volume in bearings. If you need help creating precision calculations for your equipment, consider Noria's Lubrication Program Development services. To calculate grease quantity, you need the bearings physical

Live Chat
Introduction to Wastewater Clarifier Design   Amazon S3

Introduction to Wastewater Clarifier Design Amazon S3

Introduction to Wastewater Clarifier Design . by . Nikolay Voutchkov, PE, BCEE . Because of this, the well size is designed to obtain a detention time of 20 to 30 minutes. The flocculating feedwell typically ext ends down 40 to 50% of the tank depth.

Live Chat
Process Design Manual Sludge Treatment And Disposal

Process Design Manual Sludge Treatment And Disposal

Case studies and generalized experiences will be discussed in detail to emphasize the numerous sludge treatment and disposal alternatives. Data will be presented to assist the design engineer in selecting the optimum unit processes for inclusion in a particular conceptual design.

Live Chat
High Rate Thickeners   Solid Liquid Separation

High Rate Thickeners Solid Liquid Separation

The High Rate thickeners became popular in the mid 1980's and are relatively newcomers to the sedimentation line of equipment. As already discussed previously Thickeners are a major component in a plant layout and occupy large spaces which may be saved by introducing high rate machines. Furthermore, they are normally positioned far away from

Live Chat
Process Design Manual Sludge Treatment And Disposal

Process Design Manual Sludge Treatment And Disposal

Case studies and generalized experiences will be discussed in detail to emphasize the numerous sludge treatment and disposal alternatives. Data will be presented to assist the design engineer in selecting the optimum unit processes for inclusion in a particular conceptual design.

Live Chat
HOW TO CALCULATE PAPER REEL WEIGHT   YouTube

HOW TO CALCULATE PAPER REEL WEIGHT YouTube

Nov 04, 20170183;32;To calculate the reel weight of paper it requires size, dia, core dia, and bulk of the paper. These values simply enter in my off line calculator and get the reel weight easily. https//docs

Live Chat
Liquid Separation  Thickening   ScienceDirect

Liquid Separation Thickening ScienceDirect

A variation is the tray thickener where trays or compartments are placed one on top of the other. Each tray acts as a thickener and the assembly operates in parallel with a common pier or shaft where the rakes are fixed. Clarification takes place in series operation, that is, the thickener underflow from the top compartment serves as feed to the lower compartment.

Live Chat
Measuring Settling Rates and Calculating Thickener Capacity

Measuring Settling Rates and Calculating Thickener Capacity

In order to develop rational methods of measurement and laboratory testing, it becomes necessary to study the general phenomena of settling rates. Since it was desired to give the public the benefit of these methods at as early a date as possible, together with the knowledge of the general principles of slime settling necessary for a clear understanding of the laboratory tests, we have

Live Chat
THICKENERS   Thermopedia

THICKENERS Thermopedia

The liquid, ideally containing no solids, forms the quot;overflowquot; from the thickener. Thickeners vary widely in size and configuration, but they all comprise a. a vessel to provide volume and area needed for thickening, with the area being large enough to allow the solids to settle at a velocity faster than the upward velocity of the liquid; b. a

Live Chat
Thickening   Resource Book

Thickening Resource Book

flocculants. They differ from conventional thickeners in feed well design, size and control. Unlike conventional thickeners, high rate thickeners must use flocculants. The basic design of a high rate thickener is below. High rate thickener feed wells are designed

Live Chat
Optimising thickener efficiency   sustainabilitymatters.net.au

Optimising thickener efficiency sustainabilitymatters.net.au

If the thickeners underflow is destined for a tailings dam, the optimisation of the slurry density helps to reduce negative environmental impacts through leaching at the dams. Bed mass is calculated based on the total volume of combined water and solids in the tank and the total hydrostatic pressure measured near the bottom of the tank. As

Live Chat
CHAPTER 3 SLUDGE THICKENING   Marmara 220;niversitesi

CHAPTER 3 SLUDGE THICKENING Marmara 220;niversitesi

The design involves selecting a typical solids flux and calculating the required surface area by dividing the anticipated solids feed by the flux [3]. Area of the thickener 2. Design based on Iaboratory data First Approach It is the best technique if the Iaboratory data is available. Typical test is done by using a 1000mL graduated cylinder.

Live Chat
Chapter 5 Quantities Calculations   Wyoming Department of

Chapter 5 Quantities Calculations Wyoming Department of

Chapter 5 Quantities Calculations 5 2 Apr 2007 Rev Sept 2015 Estimated quantities for the more common bridge associated bid items shall be based on the units and accuracy shown in the following table. An asterisk (*) indicates that additional information and suggested formulas to be used in quantity calculations follow the table.

Live Chat
Design Examples   Dokuz Eyl252;l University

Design Examples Dokuz Eyl252;l University

Calculation of Oxygen Requirement Calculate oxygen requirement of a complete mix activated sludge process treating domestic wastewater having flowrate of 0.25 m 3 /sec. BOD 5 concentration of settled wastewater is 250 mg/L. The effluent soluble BOD 5 is 6.2 mg/L. Increase in the mass of MLVSS is 1,646 kg/day. Assume that the temperature is 20 176;C and the conversion factor, BOD 5 / BOD L

Live Chat
Effect of settling test procedure on sizing thickeners

Effect of settling test procedure on sizing thickeners

Request PDF on ResearchGate On Feb 1, 2014, Gh.A. Parsapour and others published Effect of settling test procedure on sizing thickeners

Live Chat
Drive Wheel Motor Torque Calculations   mae.ufl.edu

Drive Wheel Motor Torque Calculations mae.ufl.edu

EML2322L MAE Design and Manufacturing Laboratory Drive Wheel Motor Torque Calculations . Step Four Determine Total Tractive Effort . The Total Tractive Effort (TTE) is the sum of the

Live Chat
Lamella clarifier

Lamella clarifier

Both the overflow stream and the underflow stream from a lamella clarifier will often require post treatment. The underflow stream is often put through a dewatering process such as a thickener or a belt press filter to increase the density of slurry. This is an important post treatment as the underflow slurry is often not able to be recycled

Live Chat
Inclined Plate Clarifier Design and Sizing    HydroFloTech

Inclined Plate Clarifier Design and Sizing HydroFloTech

Inclined Plate Clarifier (parallel plate, lamella) Theory of Operation. Basic concepts and theories of clarification. If you are unfamiliar with basic inclined plate clarifier (plate settler, parallel plate clarifier, lamella plate settler, etc.) design principles, a review of the quot;Inclined Plate Clarifier (parallel plate, lamella) Theory of Operationquot; might prove helpful.

Live Chat
formula to make the calculation of a thickener tank

formula to make the calculation of a thickener tank

Measuring Settling Rates and Calculating Thickener Capacity. Mar 19, 2017 Formula for Determining Capacity of Continuous Thickeners The diameter of the cylinder or tank used for making the test seems to have little Get Price A Critical Review of Thickener Design Methods t J Stage. thickener design that have been proposed in the

Live Chat
Solid  Liquid Separation  Thickening   ScienceDirect

Solid Liquid Separation Thickening ScienceDirect

A variation is the tray thickener where trays or compartments are placed one on top of the other. Each tray acts as a thickener and the assembly operates in parallel with a common pier or shaft where the rakes are fixed. Clarification takes place in series operation, that is, the thickener underflow from the top compartment serves as feed to the lower compartment.

Live Chat
Maximize Precious Metals Recovery with CCD Circuits and

Maximize Precious Metals Recovery with CCD Circuits and

Mar 28, 20170183;32;Maximize Precious Metals Recovery with CCD Circuits and High Density Thickeners. Posted by the fundamental formulas for calculating recovery have nothing to do with the volume or mass being processed, but are dependent upon items 1 through 3 above. our 2X drive size for the paste thickener was conservatively high. Power consumption in

Live Chat
DIFFUSED AERATION DESIGN GUIDE   University of Idaho

DIFFUSED AERATION DESIGN GUIDE University of Idaho

DIFFUSED AERATION DESIGN GUIDE INTRODUCTION Those involved in the design of diffused aeration equipment for wastewater treatment should understand the impact that process type, maintenance issues and economic considerations can have on the selection of equipment. Like many other engineering challenges, these factors are

Live Chat
Introduction to Wastewater Clarifier Design   Amazon S3

Introduction to Wastewater Clarifier Design Amazon S3

Introduction to Wastewater Clarifier Design . by . Nikolay Voutchkov, PE, BCEE . Because of this, the well size is designed to obtain a detention time of 20 to 30 minutes. The flocculating feedwell typically ext ends down 40 to 50% of the tank depth.

Live Chat
CHAPTER 12 Sludge Processing and Disposal   tn.gov

CHAPTER 12 Sludge Processing and Disposal tn.gov

sampling valves should be installed at the sludge pumps. The size of valve and piping should be at least 1 1/2 inches. 12.1.6 Sludge Piping 12.1.6.1 Size and Head Sludge withdrawal piping shall have a minimum diameter of 8 inches for gravity withdrawal and 6 inches for pump suction and discharge lines.

Live Chat
Calculation of thickener area and depth based on the data

Calculation of thickener area and depth based on the data

Chemical Engineering Science VoL. 40, No. 7, pp. 1301 1303, 1985 Printed in Great Britain. Shorter Communications 0009 2509/85 53.00 + .00 Pergamon Press Calculation of thickener area and depth based on the data of batch settling test (Received 7 June 1983; accepted 15 November 1983) vo V2 F=C w Upon rearrangement eqn (5) becomes pt\c C2 the area of a cross section is given as F=T1( ~ P

Live Chat
4 x Flowrate 4 x 200  Riserate   MIP Process Technologies

4 x Flowrate 4 x 200 Riserate MIP Process Technologies

MIP Thickener Design The following is a short cut to designing your own thickener (a) Size of Thickener As a first stab we can either use the thickener flux (m. 2 /tpd) or the rise rate, depending if solids loading is the dominant (eg.

Live Chat